Storage device performance deteriorated (2007236)
Details
Some of the possible reasons why the device latency increased are:
- Changes made on the target
- Disk or media failures
- Overload conditions on the device
- Failover
For more/related information, see Information regarding vSphere storage device latency performance metrics (2001676).
Impact
The storage device performance declines.
Example
This is an example of the message received when this occurs:
Device naa.5000c5000b36354b performance has deteriorated. I/O latency increased from average value of 1832 microseconds to 19403 microsecond
Note: The message shows microseconds which can be converted to milliseconds: 19403 microseconds = 19.403 milliseconds.
Solution
Also check if these messages are generated when there were any scheduled tasks, such as backups, replications, etc., as these can also cause intermittent performance hits.
If the message is generated because of an overload condition, attempt to reduce the load on the affected storage device. If the storage device is overloaded, reduce the load on the storage device.
If running a LUN replication tool, pause the task from the storage end and attempt a storage vMotion to a different datastore. This should help improve the I/O operations.